Showing posts with label process flow calibration system. Show all posts
Showing posts with label process flow calibration system. Show all posts

Friday, June 4, 2021

Exactly how to Calibrate a Flowmeter?



A flowmeter is a tool that is used to measure the flow rate of a gas or fluid and then shows the flow reading to the instrument operator by means of an indicator, either analog or digital output. In general, flowmeters offer vital measurement data to industry types, from pharmaceutical to Oil & Gas. The flowmeter types used here refer to closed pipe type flowmeters and not open channel systems. The flow rate denotes the average velocity at which a gas or fluid moves through the pipe. To guarantee the flow meter indicates or outputs a reliable and precise reading, the flowmeter must be calibrated consistently.

What is Flow Meter Calibration?

Calibration is the procedure of checking an instrument to check it is correct. Flowmeter calibration is the same method where the measurement is flow. Calibration of a flowmeter can be attained in one of the numerous ways, but generally includes the comparison of the flowmeter against a reference standard of higher precision. Calibration is a crucial part of an instrumentation system to promise a line of traceability of the measurement system is maintained. To understand the flowmeter performance over a period of time, flowmeter calibration must always be conducted on an “As Found” basis so meter drift analysis can be measured. With additional customer agreement, a further adjustment of the flow meter reading may be performed to reduce the flowmeter errors.

Flowmeter Calibration Processes?

We describe the various flowmeter methods and procedures associated with liquid flowmeters. Then will discuss the calibration methods for air and gas flowmeters. Liquid flow calibration can be done in numerous ways, but always includes the comparison against a standard, this may be a primary or secondary reference standard, dependent upon the precision required. The three central calibration principles for the Process flow meter calibration system use Gravimetric, Volume or transfer standard calibration methods. 

Friday, August 14, 2020

PROCESS FLOW METER CALIBRATION SYSTEM

 The Flocal Series by Nagman Instruments Consortium, a PAN India Company, sizes in meters from DN10 up to DN 400 with many more sizes presented to you. It provides a good flow rate between 1 to 25000 LPM or more depending on your requirement.

In order to make sure it suits, the ProcessFlow Meter Calibration System comes with 1, 2 or 3 lines, providing a Calibration Campaign Time from 30 seconds.

The Process Flow meter Calibration System comes with different Calibration Methods such as Gravimetric or Volumetric or Comparison with accuracies ranging from 0.2% to 0.05%.

Water, the correction factor for other liquids serves as the Calibration Media. The number of units to test depends on what suit the best – Single or Multiple.

The display or control console as some call it directs the Flow Rate, Total Flow, Start/Stop Timer and a lot more all operated Manually; Semi or Fully Automatically. Any of the operations methods could be used depending on the convenience.

The automation functions as PLC; HMI or SCADA. On the other hand, System Modules include Pumps with VFD/ Distribution Headers / Mounting Clamps / Spacers – Reducers, Adapters / Electro-Magnetic Meters (Flow Setting Masters) / Valves / Measuring Tanks / Flow Diverters / Weigh scales, Load Cells / Storage Tanks++.

Each best suited for Calibrating Flow Elements/ Electromagnetic/ Mass/ Vortex/ Ultrasonic/ PD Type Flow Meters.

The company, Nagman Instruments Consortium, was founded in the year 1972 serving the global market ever since. The organisation offers Comprehensive Calibration Solutions to customers through its various branches. The company jostles with a vision to identify niche avenues and potentials across the globe and enhance the business in the Filed Instruments and Calibration Systems.

Friday, October 18, 2019

Flow Meters


Nagman flow meters are uniquely designed with engineering perfection for various flow measuring and detecting applications.
The electromagnetic flow meters operate on the principle of EM wave deduction and widely used in all water related industries like, desalination, sludge, wastewater, industrial water treatments, cooling plants, leakage detections, water distribution and Irrigation. Nagmans Electro-Magnetic flow meters are made of graded carbon steel with quality polymers in linear cover and titanium electrodes. With sound accuracy, wide temperature range & 0.5 to 15m/s velocity, Nagman’s EM flow meters are variably instrumental in providing, controlling & delivering outputs Can be operated with normal 220AC, 24VDC supply with 3.6 volts battery.
Nagmanflow'sCoriolis mass flow meters are designed to measure liquid flow inside tubes range from 8 to 2500000 kg/hr for liquid & 4 to 2500000 kg/hr for gases. These Coriolis meters have a temp range from -50 to 200 deg Celcius & a fine accuracy range from 0.1 to 0.5.
Nagmansflow's vortex flow meters are designed to measure flow in high viscous fluids, with the principle of vortices vs flow velocity calibration. These vortex flow meters are widely used in oil, petrochemical, pharmaceutical & water treatment industries. Nagmans Vortex flow meters come with wide flow range for liquid and gases, wide temperature range and fine accuracy of 0.1.
Nagmanflow's positive displacement flow meters work in the principle of internal parts disruption by fluid flow, which tends to measure the output with the flow velocity. These positive displacement flow meters have a flow range of 0.3 m3/hr to 1800m3/hr with medium temp range from -20 to 250 deg Celcius. Proofed with anti-explosion grade pressure loss parameters, repeatability & the accuracy are its unique instrumentation merits in performance. 
Nagmanflow's ultrasonic flow Meters measures the velocity of flowing fluid with ultrasonic sound beams in volumetric. These ultrasonic flow meters come with fine accuracy 0.1, medium temperature range -10 to 160 deg Celcius & velocity to 0 to 10m/s. Ultrasonic flow meters are designed to meet versatile.

Process flow calibration systems from Nagmanflow/ Mobile flow calibration systems are customized designed instruments considering various industrial applications where required. These process flow calibration systems come with fine accuracy of 0.2 to 0.05, flow range from 1 to25000 lpm, calibration methods such as volumetric/ Gravimetric / comparison. Retrofitted with display, control and timer options, these process flow calibrations systems are embedded with PLC/ SCADA/ HMI remote control options. The all advantage is that all variants of flow meters can be used as a principle in design based on customer demand.