Showing posts with label flow meters. Show all posts
Showing posts with label flow meters. Show all posts

Tuesday, May 18, 2021

Flow Meters and Measurements From Nagmanflow

 As technology advances and new industries are industrialized, the need for precise and detailed measurements only increases. Liquid flow meters are one such ground-breaking tool created to meet this need. The Non-stop development of these instruments has served the advancement of many diverse industries and an ever-increasing variety of applications and flow measurements.

Flow Meter


According to its name, flow meters measure liquid or gas flow through a pipe and its rate of change. Various types exist with changing construction to help a wide range of purposes; though, each is built to the best likely fluid dynamic principles. Important technical features and type of meter used commonly depend on the viscosity, temperature, etc.

Today, flow meters have flagged themselves as essential instruments used in many diverse industries. Some of these industries are:

  • Ø Fuel and Oil
  • Ø Petrochemical
  • Ø Chemical
  • Ø Pharmaceutical
  • Ø Paints, Grease, and Coating
  • Ø Food and Beverages

Other than for industry use, liquid flow meters are utilized for educational purposes in university science and engineering programs. They are also used in housing projects to determine the amount of water utilized.

Engineers have created liquid flow meters that can withstand extreme conditions such as outdoor temperature and pressure; irrespective of the weather conditions, we have developed meters that give exact results. Control valves are frequently used in conjunction with these instruments for the extended application of directing the fluid and regularizing velocity, hence maintaining the required pressure level.

The use of liquid flow meters has usage outside of measurements, such as helping to control the velocity of a fluid and its use. They can also save water from being wasted by spotting leakage in pipes.

Tuesday, January 19, 2021

Ultrasonic Flow Meters From Nagmanflow

 Ultrasonic flow meters use sound waves to define the velocity of a fluid flowing in a pipe. At no flow conditions, the frequencies of an ultrasonic wave diffused into a pipe and its replications from the fluid are the same. Under flowing conditions, the frequency of the replicated wave is different due to the Doppler Effect. When the fluid moves faster, the frequency shift surges linearly. The transmitter routes signals from the transmitted wave and its reflections to regulate the flow rate.

The ultrasonic flow meters send and receive ultrasonic waves amid transducers in both the upstream and downstream ways in the pipe. At no flow circumstances, it takes the same time to travel upstream and downstream amongst the transducers. In flowing settings, the upstream wave will move gentler and take more time than the downstream wave. When the fluid moves faster, the variance between the upstream and downstream times rises.

Ultrasonic flow meters are usually applied to measure the velocity of liquids that permit ultrasonic waves to pass, such as water, molten sulfur, cryogenic liquids, and chemicals. Transit time designs are also accessible to measure gas and vapor flow. Since fluids that do not pass ultrasonic energy, such as many types of slurry, restrict the penetration of ultrasonic waves into the fluid. In ultrasonic flowmeters, opaque fluids can restrict ultrasonic wave diffusion too near the pipe wall, which can reduce accuracy and make the flowmeter to measure wrongly. The ultrasonic flowmeters can stop functioning when an opaque fluid declines the ultrasonic wave to such a level that the wave does not touch the receiver.

 Be sure that the fluid can sufficiently conduct ultrasonic waves, since the flow measurements will not quantity when the ultrasonic waves cannot pierce the flow stream between the transducers. Likewise, ultrasonic waves must be able to infiltrate the fluid for Doppler flowmeters to operate perfectly. While the fluid is moderately opaque and does not enter the fluid, the flowmeters tend to quantity the velocity of the fluid at or near the pipe wall, which can cause substantial measurement error and cause the flowmeter to fail.

Saturday, November 28, 2020

Vortex Flow Meters From Nagmanflow

 The recent choice for the gas, steam flow, and liquid measurement is Vortex flow meters that are used for measuring the supersaturated and saturated steam to improve the capability and allocation in large facilities. The main applications of Vortex flow meters are volumetric water flow and high flow gas facilities. They are used in steam, liquid, and gas industrial flow applications. It uses the fluid dynamics principle of vortex shedding that helps to calculate the velocity of gases, steam, and liquids.



The Vortex works with the use of a dimensional bluff, known as a shedder bar, in which the vortices begin to form and oscillate. The natural frequency of these vortices is converted into a digital signal which is then processed through the meter’s electronics to calculate the flow. The advantages are it is accurate and for measuring the flow. This method of measurement can be used with many types of fluids, steam, and even gases. As the Vortex flow meters lack moving mechanical components makes its construction more robust that can handle the toughest application environments.



The vortex flowmeters are used in Oil Industries, water treatment plants, Pharmaceuticals, and Petrochemical industries. In Nagman we provide you with a lot of options and varieties of flow meters with good quality and we also provide you the assistance needed for the whole process for your industries with more equipment needed for your Industry.

Saturday, October 24, 2020

Positive Displacement Flow Meters From Nagman Flow

Positive Displacement flow meters are the best flow measuring equipment to openly measure the volume of fluid that travels through the flow meter. It attains this by trapping pockets of fluid amongst rotating components housed inside a high precision chamber. This can be associated to recurrently filling a beaker with fluid and pouring the contents downstream while calculating the number of times the beaker is filled. Rotor rotational velocity is directly related to flow rate since the flow of fluid is instigating the rotation.




 

 In the case of electro magnetic flow meters, the rotating components involve magnets that trigger numerous sensor options located exterior to the fluid chamber. Mechanical positive shift flow sensors rely on the rotation to drive either a magnetic coupling or a direct gear train related to the mechanical counter.

 

 Positive Displacement flow meters do not gratify a power supply for their operation and do not need straight upstream and downstream pipe runs for their setting up. Positive displacement flow meters are obtainable in sizes from in to 12 in and can function with turndowns as great as 100:1, although ranges of 15:1 or lower are much more communal. The slippage between the flow meter constituents is reduced and metering precision is consequently increased as the thickness of the process fluid increases.

 

 The process fluid must be spotless. Particles greater than 100 microns in size must be detached by filtering. PD meters work with small clearances amid their precision-machined parts which worn out speedily and rescind their accuracy. For this reason, Positive Displacement flow meters are generally not suggested for measuring slurries or coarse fluids. In fresh fluid services, nevertheless, their precision and wide rangeability make them perfect for custody transfer and group charging. They are most extensively used as household water meters. Millions of such units are formed annually. In industrial and petrochemical applications, Positive displacement flow sensors are normally used for batch charging of both liquids and gases.

 

 While slippage through the positive displacement flow meters declines that is, correctness increases as fluid viscosity increases, the pressure drop through the meter also increases. Subsequently, the maximum and minimum flow capacity of the flow meter is reduced as viscosity surges. The greater the viscosity, the less slippage and the lesser the measurable flow rate becomes. 


Tuesday, September 15, 2020

Nagmanflow's Flow Meters and the complete study

         A flow meters is a device used to calculate the linear, the nonlinear, mass and volumetric flow rate of a fluid or a gas. When selecting the flow meters, one ought to think about such subtle factors as expertise of plant personnel, their knowledge with calibration and maintenance, spare parts accessibility, and meantime linking failure history, etc., at the particular plant site. It is also suggested that the cost of the installation be calculated only after taking these steps.




     One of the most general flow measurement mistakes is the reverse of this sequence: instead of picking a sensor which will execute correctly, an effort is made to justify the use of a device since it is less expensive. Those "inexpensive" purchases can be the most expensive installations. This blog will help you comprehend flow meters, and you can also converse to our application engineers at any time if you have any particular flow measurement challenges.

  

        The primary step in flow sensor variety is to resolve if the flow rate information should be constant or totalized and should consider if this information is required locally or remotely. If a little, how should the transmission be? Should the transmission be analogue, digital, or shared? And, if shared, what should be the minimum data-update frequency. And if an answer is derived from the question, an assessment of the properties and flow uniqueness of the process liquid, and of the piping that will house the flow meter, must take place. To come up to this task in a methodical manner, forms have been developed, so that the following types of data are entered for each application.

  


 

 

    The fluid and its specified pressure, temperature, permissible pressure drop, density, conductivity, viscosity and vapour pressure at highest operating temperature are listed, jointly with a suggestion of how these properties might vary or interact. In toting up, all security or toxicity levels should be provided, collectively with exhaustive data on the fluid's composition, presence of bubbles, solids, tendency to coat, and light transmission qualities.

 

    Probable minimum and maximum pressure and temperature values must be given in adding to the usual operating values whilst choosing flow meters. Can the flow reverse, will it always fill the pipe, does the slug flow can develop air-solids-liquid, if aeration or pulsation is probable, can the sudden temperature changes can happen, or only particular precautions are required throughout cleaning and maintenance, these particulars, too, should be confirmed.


       Regarding the piping and the region where the flow meters are to be located, consider: For the piping, its course must avoid downhill flow in liquid applications, size, material, and schedule. The engineer ought to identify if vibration or magnetic fields are present or likely in the area if electric or pneumatic power exists, if the spot is classified for explosion hazards, or if there are previous exceptional requirements such as observance with sanitary or clean-in-place (CIP) regulations.

Monday, January 6, 2020

Types Of Level Transmitters From Nagmanflow

Level Transmitters

Nagman calibration LLC a unit of Nagman Instruments PVT ltd is the first calibration laboratory in India to be accredited with ISO/IEC 17025 standards and NABL empanelled auditors & quality control Inspectors with ISO9001/14001for total calibration solutions. Nagman calibration labs in Chennai & Mumbai covers all scientific parameters like Thermoelectric, Mechanical (Pressure, vacuum, flow, temperature, level, mass, dimension and volume) & fluid flow (Process flow meter & water calibration meter). The centres are also equipped with sophisticated calibration equipment and computerized automated calibration reporting of primary/secondary transfers of data.  

Flow meter calibration can be divided into four sections, namely LEVEL, liquid, gas & mobile flow calibration meters.
LEVEL calibrations use Electrical / Electronic and Pneumatic Consoles are housed in a sleek Panel / Test Bench Rack, designed ergonomically; a stand-alone Hydro (Water) Intensifier Unit caters to Pressure Tests. With Built-in Intelligent Software (with the facility of Retrieving / Recording / Interpreting & Displaying the Readings / Values received from various Test and Standard Instruments in easily understandable/user-friendly format) is provided for generation of Calibration Certificate / Chart / Report.
Nagmanflow’s Types of Level Calibrators
Nagman’s Radar Level Transmitter – NAGLEV 6G Series
Operates with the antenna system in principle of microwave transmitted signal with a short pulse, high frequency & resolution. The measurement time which is quick makes this a known for accurate measurement in Industrial circle. Even in complex & critical conditions these Radar level transmitters use false echoes with embedded software connected to the sensor, for processing & debugging the level accurately.
Nagman has six types of Radar level transmitting meters, namely QTRD 801 to 806. All these have a measurement precision of ± 10mm, with a temperature range from -40 to 400 degree Celsius. The main aspects that differentiate these radar level transmitters are the scientific proprieties in Industrial scale-like corrosive both light & high, pressure variance, and solid, sticky, viscous, dielectric & mixed liquid/temperature mediums.
Nagman’s all radar level transmitters are intrinsically safe with EXIAICC T6Ga flameproof quality standards and made with stainless steel body/Aluminum shell protection cover.
Nagman’s Radar Level Transmitter – NAGLEV 2G Series
Operates with the same principle of 6G series but has more potential radar sensor with high frequency and embedded with new fast microprocessors to the antenna for accurate readings. Nagman’s 2G series is resilient to all sorts of external turbulences such as pollution, corrosion, temperature/pressure distortions.
Nagman’s 2G Radar level transmitting meter models are HTRD 601 to 906 series, with measuring range up to 70 meters, Accuracy range from:±3 to:±15mm in models, the Temperature range of -40 to -250 degree Celsius & process pressure of 0.1 to 0.4 MPA. 
Both handheld and mounted models are available as per requirements with fixed with LCD display. Installation methods and techniques can be referred through Nagman’s catalogues.
NAGLEV Series GWR
Nagman’s Guided Wave Radar meter operates in the principle of Reflected pulse signal along the cable or rod probe-type transmit to the instrument electronic circuit parts, the microprocessor processes the signal, identify the microwave pulse-echo generated in the material surface. Correct identification of the echo signal have completed the implementation by the pulse software.
Nagman’s guided wave radar meter has five models from gwr 701 to 705, with measuring range from 6 to 30 meters based on models, the precision of ± 10mm, Frequency of 500 MHZ to 1.8GHZ & a wide temperature range of -40 to 400 degree Celsius.
Nagman’s Ultrasonic Level Transmitter – NAGLEV Series US
Operates on the principle of; sensor of the meter pulses in the direction of the product surface. There, they are reflected back and received by the sensor. The meter measures the time t between pulse transmission and reception. The meter uses the time t (and the velocity of sound) to calculate the distance D between the sensor membrane and the product surface. In gas mediums the ultrasonic velocity of the gas is influenced by the gas temperature, so the material level meter compensates sound velocity for the gas temperature at work.
Product Introduction Model Parameters US 4 US 6 US 8 US 10 US 12 US 20 US 30 Application Industrial Level Measurement Measuring Range liquid:0.2-4 m liquid:0.25-6 m liquid:0.3-8 m liquid:0.4-1 0m liquid:0.5-12 m liquid:0.8-20 m liquid:1.2-30 m Process Connection G2 Thread M95X2.0Thread Energy Transducer Material ABS,PVC,PTFE Temperature -40~ 75 Deg C (LCD:-20ºC~ +70ºC) Temperature compensation The whole range with automatic compensation Process Pressure ±0.1MPa Precision 0.2% of actual range Signal output 4-20mA(Option: RS485 / HART/ Alarm) Power Supply DC20V~32 ≥30mA Display Resolution Ratio 1mm Mode of Indication 4 Digit LCD Cable Diameter Ø 6-12mm Single Wire Diameter Ø 0.5-1.78mm Cable Entry/Seal M20/PG13.5 Beam Angle 8º(3db) Measurement Cycle 1.5 seconds.
Features are Integrated design, installed conveniently; Protected in the excessive voltage and current, protected in the thunder and lightning. The big show window of LCD is easy to debug and observe;  Over-voltage over-current protection, lightning protection;  Advanced since the clamp type terminal, to ensure that wiring never loose;  Intellectual signal treatment technology, guarantee that the instrument meets various kinds of operating occasion;  All plastic probe, acid and alkali resistant, adapt to bad environment.

Friday, November 22, 2019

Why is Ultrasonic flow meters becoming a favourite choice in the Industry?

Ultrasonic Flow Meters

 The Ultrasonic flow meters operate on the principle of Ultrasonic sound waves when passed through a flow pipe, determining the velocity of the fluid in it. When there is no flow in the pipe, the frequency of the ultrasonic sound waves gives out the same input frequency. When there is a flow inside the pipe, the frequency of the Ultrasonic flow meters increase in response with the speed of flow in Linear.

Nagman Instruments a pan India Company since 1972, with global supply, is a pioneer in Instrumentation & calibration systems. The company with its five types of flow meters that operates on by principles, has introduced a versatile Ultrasonic flow meter that can be used in various industrial applications. Nagman Ultrasonic flow meter comes with a wall mounted & handheld with three types of sensors S2, L2 & M2 that can be fitted with purpose applications. Virtually supports all sorts of fluid and liquid flow in Industrial applications. Interfaced through RS 232 communication mode; it comes with a 7 digit totals for positive and negative flow. Nagman Ultrasonic flow meter has a temperature range of -10 to 160 deg Celcius, Sound accuracy of  ±1% of Reading at rates > 0.2 mps, velocity of 0 to 10m/s.


Why is Ultrasonic flow meters becoming a favourite choice in the Industry?

Ultrasonic flow metres when compared to other types based on their principles of working, has its own salient features.
-          Ultrasonic flow meters have less connected parts or in other words devoid of internal design complexity.
-          Its working principle just depends on a beam of sound waves passed through the pipe medium which makes it a precise and accurate measuring in flow meters.
-          The frequency variation does not distort or trouble the flow of fluid in pipes, as it just a sound wave passing through or transmitted across the medium.
-          Ultrasonic flow meters are versatile with wall-mounted and handheld options in AC/DC supply.

  Flow meter hire is the same ultrasonic flow meter with hiring (use & return) option. The Instrument, when required for a short period time in measuring flow in pipes in certain critical & remote applications, can make use of the flow meter hire. Not all industrial applications are in the house in piping and flow. Many applications are external in offshore and onshore with pipelines. So Ultrasonic flow meter hire options enhances the safety and reliability of piping systems in those areas, with its accurate and steady working principle.