Friday, August 14, 2020

PROCESS FLOW METER CALIBRATION SYSTEM

 The Flocal Series by Nagman Instruments Consortium, a PAN India Company, sizes in meters from DN10 up to DN 400 with many more sizes presented to you. It provides a good flow rate between 1 to 25000 LPM or more depending on your requirement.

In order to make sure it suits, the ProcessFlow Meter Calibration System comes with 1, 2 or 3 lines, providing a Calibration Campaign Time from 30 seconds.

The Process Flow meter Calibration System comes with different Calibration Methods such as Gravimetric or Volumetric or Comparison with accuracies ranging from 0.2% to 0.05%.

Water, the correction factor for other liquids serves as the Calibration Media. The number of units to test depends on what suit the best – Single or Multiple.

The display or control console as some call it directs the Flow Rate, Total Flow, Start/Stop Timer and a lot more all operated Manually; Semi or Fully Automatically. Any of the operations methods could be used depending on the convenience.

The automation functions as PLC; HMI or SCADA. On the other hand, System Modules include Pumps with VFD/ Distribution Headers / Mounting Clamps / Spacers – Reducers, Adapters / Electro-Magnetic Meters (Flow Setting Masters) / Valves / Measuring Tanks / Flow Diverters / Weigh scales, Load Cells / Storage Tanks++.

Each best suited for Calibrating Flow Elements/ Electromagnetic/ Mass/ Vortex/ Ultrasonic/ PD Type Flow Meters.

The company, Nagman Instruments Consortium, was founded in the year 1972 serving the global market ever since. The organisation offers Comprehensive Calibration Solutions to customers through its various branches. The company jostles with a vision to identify niche avenues and potentials across the globe and enhance the business in the Filed Instruments and Calibration Systems.

Wednesday, February 26, 2020

All You Need To Know About Level Transmitter


A Level Transmitter is an instrument that provides a continuous level measurement. It is used to find the number of particular states of matter at a selected time – which suggests that liquid, gas, of semi-solid substances, are measured by a level transmitter.



The principle is the instrument has various types that are used for various uses. The pressure of the matter is a huge concern to pick the right Level Transmitter. It can be measured in three different ways:

  • The weight of the fluid
  • The pressure head of the fluid
  • The position of the fluid in a container

When you speak about level measurement, it is classified into two types: direct measurement and indirect measurement also known as, contact or non-contact transmitters. Direct Measurement of Contact Transmitters is considered for small level changes, which are observed in various industrial tanks. However, it must be noted that the Transmitters are mostly designed for indirect measurement. 
     

The various types of Level transmitters are as follows:

  1. Capacitance Level Transmitters
  2. Hydrostatic Level Transmitters
  3. Magnetic Level Transmitters
  4. Radar Fill Level Transmitters
  5. Ultrasonic Level Transmitter
  6. Guided Microwave Level Transmitters

If individuals are in the requirement of Level transmitters for industrial requirements – Nagman is the destination for the product. Level Transmitter are suitable for the enhancement of your business and industry – make sure you choose the right one.



Thursday, February 20, 2020

An Introduction to Flow Meter


          A flow meter is an apparatus that is used to gauge and evaluate the volume of a gas or liquid substance. They can be acknowledged as flow gauge, flow indicator, liquid meter, and flow rate sensor. Rivers and Streams can be measured using the flow meters. Improving the accuracy, precision, and resolution of flow measurement is the greatest benefit of flow meters.



Flow Meters are used to provide clear-cut monitoring. There are various kinds of flow meters in the market, but one must be clear and understand the kind of flow meter they require and is in sync with their current requirements. 

One must choose the right technology and a few important points must be remembered when you think about purchasing a flow meter. 

  • The type of Gas or Liquid that is being measured 
  • Least amount and maximum flow rates 
  • Based on your requirement – the accuracy requirement. 
  • The temperature and viscosity of the fluid or gas.
  • The compatibility of the materials 
  • The maximum limit of the pressure 
  • The amount of pressure that can be allowed 
  • Is the meter mounted? Where is the meter mounted? Look at the location before mounting. 
  • Is fluid flow continuous? 
  • The type of output you require – the kind of readout you need. 

Choose Nagman’s FlowMeters to get the best and accurate requirement with respect to your needs and technological advancements. One must understand the right flow meter to implement to get the right set of & apt readings with respect to their business and industry. 

Monday, January 6, 2020

Types Of Level Transmitters From Nagmanflow

Level Transmitters

Nagman calibration LLC a unit of Nagman Instruments PVT ltd is the first calibration laboratory in India to be accredited with ISO/IEC 17025 standards and NABL empanelled auditors & quality control Inspectors with ISO9001/14001for total calibration solutions. Nagman calibration labs in Chennai & Mumbai covers all scientific parameters like Thermoelectric, Mechanical (Pressure, vacuum, flow, temperature, level, mass, dimension and volume) & fluid flow (Process flow meter & water calibration meter). The centres are also equipped with sophisticated calibration equipment and computerized automated calibration reporting of primary/secondary transfers of data.  

Flow meter calibration can be divided into four sections, namely LEVEL, liquid, gas & mobile flow calibration meters.
LEVEL calibrations use Electrical / Electronic and Pneumatic Consoles are housed in a sleek Panel / Test Bench Rack, designed ergonomically; a stand-alone Hydro (Water) Intensifier Unit caters to Pressure Tests. With Built-in Intelligent Software (with the facility of Retrieving / Recording / Interpreting & Displaying the Readings / Values received from various Test and Standard Instruments in easily understandable/user-friendly format) is provided for generation of Calibration Certificate / Chart / Report.
Nagmanflow’s Types of Level Calibrators
Nagman’s Radar Level Transmitter – NAGLEV 6G Series
Operates with the antenna system in principle of microwave transmitted signal with a short pulse, high frequency & resolution. The measurement time which is quick makes this a known for accurate measurement in Industrial circle. Even in complex & critical conditions these Radar level transmitters use false echoes with embedded software connected to the sensor, for processing & debugging the level accurately.
Nagman has six types of Radar level transmitting meters, namely QTRD 801 to 806. All these have a measurement precision of ± 10mm, with a temperature range from -40 to 400 degree Celsius. The main aspects that differentiate these radar level transmitters are the scientific proprieties in Industrial scale-like corrosive both light & high, pressure variance, and solid, sticky, viscous, dielectric & mixed liquid/temperature mediums.
Nagman’s all radar level transmitters are intrinsically safe with EXIAICC T6Ga flameproof quality standards and made with stainless steel body/Aluminum shell protection cover.
Nagman’s Radar Level Transmitter – NAGLEV 2G Series
Operates with the same principle of 6G series but has more potential radar sensor with high frequency and embedded with new fast microprocessors to the antenna for accurate readings. Nagman’s 2G series is resilient to all sorts of external turbulences such as pollution, corrosion, temperature/pressure distortions.
Nagman’s 2G Radar level transmitting meter models are HTRD 601 to 906 series, with measuring range up to 70 meters, Accuracy range from:±3 to:±15mm in models, the Temperature range of -40 to -250 degree Celsius & process pressure of 0.1 to 0.4 MPA. 
Both handheld and mounted models are available as per requirements with fixed with LCD display. Installation methods and techniques can be referred through Nagman’s catalogues.
NAGLEV Series GWR
Nagman’s Guided Wave Radar meter operates in the principle of Reflected pulse signal along the cable or rod probe-type transmit to the instrument electronic circuit parts, the microprocessor processes the signal, identify the microwave pulse-echo generated in the material surface. Correct identification of the echo signal have completed the implementation by the pulse software.
Nagman’s guided wave radar meter has five models from gwr 701 to 705, with measuring range from 6 to 30 meters based on models, the precision of ± 10mm, Frequency of 500 MHZ to 1.8GHZ & a wide temperature range of -40 to 400 degree Celsius.
Nagman’s Ultrasonic Level Transmitter – NAGLEV Series US
Operates on the principle of; sensor of the meter pulses in the direction of the product surface. There, they are reflected back and received by the sensor. The meter measures the time t between pulse transmission and reception. The meter uses the time t (and the velocity of sound) to calculate the distance D between the sensor membrane and the product surface. In gas mediums the ultrasonic velocity of the gas is influenced by the gas temperature, so the material level meter compensates sound velocity for the gas temperature at work.
Product Introduction Model Parameters US 4 US 6 US 8 US 10 US 12 US 20 US 30 Application Industrial Level Measurement Measuring Range liquid:0.2-4 m liquid:0.25-6 m liquid:0.3-8 m liquid:0.4-1 0m liquid:0.5-12 m liquid:0.8-20 m liquid:1.2-30 m Process Connection G2 Thread M95X2.0Thread Energy Transducer Material ABS,PVC,PTFE Temperature -40~ 75 Deg C (LCD:-20ºC~ +70ºC) Temperature compensation The whole range with automatic compensation Process Pressure ±0.1MPa Precision 0.2% of actual range Signal output 4-20mA(Option: RS485 / HART/ Alarm) Power Supply DC20V~32 ≥30mA Display Resolution Ratio 1mm Mode of Indication 4 Digit LCD Cable Diameter Ø 6-12mm Single Wire Diameter Ø 0.5-1.78mm Cable Entry/Seal M20/PG13.5 Beam Angle 8º(3db) Measurement Cycle 1.5 seconds.
Features are Integrated design, installed conveniently; Protected in the excessive voltage and current, protected in the thunder and lightning. The big show window of LCD is easy to debug and observe;  Over-voltage over-current protection, lightning protection;  Advanced since the clamp type terminal, to ensure that wiring never loose;  Intellectual signal treatment technology, guarantee that the instrument meets various kinds of operating occasion;  All plastic probe, acid and alkali resistant, adapt to bad environment.

Friday, November 22, 2019

Why is Ultrasonic flow meters becoming a favourite choice in the Industry?

Ultrasonic Flow Meters

 The Ultrasonic flow meters operate on the principle of Ultrasonic sound waves when passed through a flow pipe, determining the velocity of the fluid in it. When there is no flow in the pipe, the frequency of the ultrasonic sound waves gives out the same input frequency. When there is a flow inside the pipe, the frequency of the Ultrasonic flow meters increase in response with the speed of flow in Linear.

Nagman Instruments a pan India Company since 1972, with global supply, is a pioneer in Instrumentation & calibration systems. The company with its five types of flow meters that operates on by principles, has introduced a versatile Ultrasonic flow meter that can be used in various industrial applications. Nagman Ultrasonic flow meter comes with a wall mounted & handheld with three types of sensors S2, L2 & M2 that can be fitted with purpose applications. Virtually supports all sorts of fluid and liquid flow in Industrial applications. Interfaced through RS 232 communication mode; it comes with a 7 digit totals for positive and negative flow. Nagman Ultrasonic flow meter has a temperature range of -10 to 160 deg Celcius, Sound accuracy of  ±1% of Reading at rates > 0.2 mps, velocity of 0 to 10m/s.


Why is Ultrasonic flow meters becoming a favourite choice in the Industry?

Ultrasonic flow metres when compared to other types based on their principles of working, has its own salient features.
-          Ultrasonic flow meters have less connected parts or in other words devoid of internal design complexity.
-          Its working principle just depends on a beam of sound waves passed through the pipe medium which makes it a precise and accurate measuring in flow meters.
-          The frequency variation does not distort or trouble the flow of fluid in pipes, as it just a sound wave passing through or transmitted across the medium.
-          Ultrasonic flow meters are versatile with wall-mounted and handheld options in AC/DC supply.

  Flow meter hire is the same ultrasonic flow meter with hiring (use & return) option. The Instrument, when required for a short period time in measuring flow in pipes in certain critical & remote applications, can make use of the flow meter hire. Not all industrial applications are in the house in piping and flow. Many applications are external in offshore and onshore with pipelines. So Ultrasonic flow meter hire options enhances the safety and reliability of piping systems in those areas, with its accurate and steady working principle.

Sunday, October 20, 2019

Flow Meter Calibration system


Flowmeter calibration can be divided into four sections, namely level, liquid, gas & mobile flow calibration meters.

Level calibrations use Electrical / Electronic and Pneumatic Consoles are housed in a sleek Panel / Test Bench Rack, designed ergonomically; a stand-alone Hydro (Water) Intensifier Unit caters to Pressure Tests. With Built-in Intelligent Software (with the facility of Retrieving / Recording / Interpreting & Displaying the Readings / Values received from various Test and Standard Instruments in easily understandable/user-friendly format) is provided for generation of Calibration Certificate / Chart / Report.
 Types of level Instruments –best Suited for
Tests that can be performed
                               Float type level instruments
                            Linearity
                               Displacer
                            Dead band
                               Radar
                           Sensitivity & Resolution
                               Capacitance
                            Pressure test
                               Ultrasonic
                            Hysteresis
                               Magnetic
                            Repeatability
                            Built-in & External chamber
                            Functional
.
Nagmanflow’s Water meter calibration system is most suited for verifying / Calibrating – Domestic Water Meters of Sizes from DN 15 to DN 50 and Bulk/Industrial meters of Sizes above DN 50 up to DN 300.
Complete Integrated System with Pumps (with VFD), Rotameters or Flow meters / Manual or Automatic Throttles for Flow Rate Control. Reservoir, Test Bed with Quick Clamping Systems / Spacers & Blanks and Electric Control Console / Calibration Software.
Boon to Water Boards / Jal Nigam / Municipal Corporations / OEMs & Calibration Labs
Best Suited for Single JET, Multi Jet, Electromagnetic and Ultrasonic water meters covering AMI / AMR features.
Nagmans gas Calibration Standard’ of the Test Bench is “Bell Prover”, which is considered a Primary (Calibration) Standard to Test & Calibrate Domestic Gas Meters (& Gas Meters used in Hotels/Restaurants etc.). The device is ideal for OEMs, Calibration Laboratories & Calibration Service Providers.
The Test Bench, with 2 Sizes of Bell Prover (20L & 100L)will effectively cover Very Low (Qmin – typically 0.016 m3/h (0.27 LPM)) to Maximum (Qmax – 6 m3/h (100 LPM)) Flow Rates. Available Accuracies : 0.2% & 0.5% F.S.
Upto 4 Gas Meters can be connected (inserted) during a campaign. Facility provided for continuously monitoring Differential Pressures (DP) across each Meter as well as upstream & downstream Line Pressures & Line Temperatures. Line Pressures are regulated typically around 500Pa.
Nagman’s BELL PROVER

Bell prover helps the gas flow meter test bench to sample and calibrate the gas flow. It can test rota meter, gas meter, and other forms of a gas flow meter. The bell prover can move up and down automatically and the gas-output valve can switch automatically.
The Bell prover and liquid cell form a sealed space of variable volume. When the Bell moves down into the sealed liquid, through pressure compensation mechanism, the internal gas pressure does not vary along with the changed depth of the sealed liquid. Meanwhile, the gas in the Bell is exhausted to the flow meters through a connect pipe. The exhausted gas volume will be detected compared with the cumulative in the meters.
Sizes
  G 1.6 to 6
Working pressure
  1 KPa to 5 KPa
Flow range
  0.2 m3 / hr. to 120 M3/hr
Accuracy
  0.2 to 0.2%

Nagmanflow’s Sonic Nozzle

A “sonic nozzle” (also known as “Critical Flow Venturi” or “Critical Flow Nozzle”) is a flow meter that can be used as a calibration standard for gas flow meters or any flow measurement device. By design, sonic nozzles are a constant volumetric flow meter.
The nozzles are designed and manufactured to the ISO standard and as such the gas is accelerated along the Bell Mouth converging section and then is expanded in a conical diverging section, which is designed for pressure recovery. In the throat or minimum area point of the Sonic Nozzle, the gas velocity becomes equal to the speed of sound. At this point, gas velocity and density are maximized, and the mass flow rate is a function of the inlet pressure, inlet temperature, and the type of gas. So, you only need to measure the inlet pressure and temperature to determine the flow rate.


Friday, October 18, 2019

Flow Meters


Nagman flow meters are uniquely designed with engineering perfection for various flow measuring and detecting applications.
The electromagnetic flow meters operate on the principle of EM wave deduction and widely used in all water related industries like, desalination, sludge, wastewater, industrial water treatments, cooling plants, leakage detections, water distribution and Irrigation. Nagmans Electro-Magnetic flow meters are made of graded carbon steel with quality polymers in linear cover and titanium electrodes. With sound accuracy, wide temperature range & 0.5 to 15m/s velocity, Nagman’s EM flow meters are variably instrumental in providing, controlling & delivering outputs Can be operated with normal 220AC, 24VDC supply with 3.6 volts battery.
Nagmanflow'sCoriolis mass flow meters are designed to measure liquid flow inside tubes range from 8 to 2500000 kg/hr for liquid & 4 to 2500000 kg/hr for gases. These Coriolis meters have a temp range from -50 to 200 deg Celcius & a fine accuracy range from 0.1 to 0.5.
Nagmansflow's vortex flow meters are designed to measure flow in high viscous fluids, with the principle of vortices vs flow velocity calibration. These vortex flow meters are widely used in oil, petrochemical, pharmaceutical & water treatment industries. Nagmans Vortex flow meters come with wide flow range for liquid and gases, wide temperature range and fine accuracy of 0.1.
Nagmanflow's positive displacement flow meters work in the principle of internal parts disruption by fluid flow, which tends to measure the output with the flow velocity. These positive displacement flow meters have a flow range of 0.3 m3/hr to 1800m3/hr with medium temp range from -20 to 250 deg Celcius. Proofed with anti-explosion grade pressure loss parameters, repeatability & the accuracy are its unique instrumentation merits in performance. 
Nagmanflow's ultrasonic flow Meters measures the velocity of flowing fluid with ultrasonic sound beams in volumetric. These ultrasonic flow meters come with fine accuracy 0.1, medium temperature range -10 to 160 deg Celcius & velocity to 0 to 10m/s. Ultrasonic flow meters are designed to meet versatile.

Process flow calibration systems from Nagmanflow/ Mobile flow calibration systems are customized designed instruments considering various industrial applications where required. These process flow calibration systems come with fine accuracy of 0.2 to 0.05, flow range from 1 to25000 lpm, calibration methods such as volumetric/ Gravimetric / comparison. Retrofitted with display, control and timer options, these process flow calibrations systems are embedded with PLC/ SCADA/ HMI remote control options. The all advantage is that all variants of flow meters can be used as a principle in design based on customer demand.